The Wilo Star Z Nova solar hot water pump is the current replacement for the discontinued Salmson SB 04-15 and NSB 04-15 circulation pumps used in many Australian systems.
If your solar hot water system is not circulating properly, making noise, or failing to heat efficiently, this pump provides a reliable and energy-efficient replacement designed for long-term performance.
Trusted replacement used across thousands of Australian solar hot water systems.
✔ Common reasons for replacement
- No hot water or poor heating
- Pump not running
- Loud or vibrating pump
- System overheating
✔ Suitable for systems including
- Rheem solar hot water systems
- Dux solar systems
- Apricus systems
- Hills systems
- Solahart systems
✔ Why upgrade to the Wilo Star Z Nova?
- Replaces older, discontinued Salmson pumps
- Improved energy efficiency (lower running costs)
- Quiet, modern operation
- Designed for continuous solar circulation
✔ Replaces older models
- Salmson SB 04-15
- Salmson NSB 04-15
- Wilo Z15 / Z15A
✔ Why choose the Wilo Star Z Nova?
- Energy-efficient operation (low power consumption)
- Quiet running
- Reliable modern design
- Designed for continuous hot water circulation
What is the difference between Salmson and Wilo pumps?
Salmson pumps are the older models that were widely used in solar hot water systems. These have now been discontinued and replaced by Wilo pumps, which are the updated versions offering improved efficiency, reliability and modern design.
The Wilo Star Z Nova is one of the most commonly used solar hot water circulation pump replacements in Australia.
✔ Installation notes
- Installed inline with your solar hot water system
- May require minor pipe adjustments depending on setup
- Professional installation recommended
Is the Wilo Star Z Nova a replacement for the Salmson SB 04-15?
Yes, the Wilo Star Z Nova is widely used as a replacement for the discontinued Salmson SB 04-15 and earlier models. It is suitable for most systems that previously used these pumps.
Will this pump fit my system?
The Wilo Star Z Nova is compatible with many Australian solar hot water systems including Rheem, Dux, Apricus, Hills and Solahart. If unsure, contact us to confirm suitability.
Is it better to replace or repair my pump?
In most cases, replacing the entire pump is more reliable than replacing internal components, especially for older or discontinued models.
Do I need a plumber to install it?
Installation by a licensed plumber or qualified technician is recommended to ensure safe and correct operation.
Pump for pipe installation, blocking-current proof synchronous motor with high starting torque. Brass pump housing, Noryl impeller, ceramic shaft.
Power consumption of 3 – 5 W.
Equipped with thermal insulation shell as standard, housing thread Rp ½.
| Hydraulic data |
| Maximum operating pressure PN
|
10 bar |
| Delivery head for Qmin H Qmin
|
1.0 m |
| Max. volume flow Qmax
|
0.4 m³/h |
| Min. fluid temperature Tmin
|
2 °C |
| Max. fluid temperature Tmax
|
95 °C |
| Min. ambient temperature Tmin
|
2 °C |
| Max. ambient temperature Tmax
|
40 °C |
| Max. permitted total water hardness |
3.57 mmol/l (20°dH) |
| Motor data |
| Mains connection |
1~230 V, 50 Hz |
| Rated power P2
|
5 W |
| Rated current IN
|
0.05 A |
| Max. speed nmax
|
3000 1/min |
| Power consumption P1 min
|
3 W |
| Power consumption P1 max
|
5 W |
| Interference emission |
EN 61000-6-3 |
| Interference immunity |
EN 61000-6-2 |
| Protection class motor |
IP42 |
| Insulation class |
F |
| Threaded cable connection |
1 x PG11 |
| Motor protection |
no |
| Materials |
| Pump housing |
Brass |
| Impeller |
PPE/PS-GF30 |
| Shaft |
Ceramic |
| Bearing |
Carbon, synthetic resin-impregnated |
| Installation dimensions |
| Thread |
G 1 |
| Pipe connection on the suction side DNs
|
Rp ½ |
| Pipe connection on the discharge side DNd
|
Rp ½ |
| Port-to-port length L0
|
84 mm |
| Installation dimensions |
| Thread |
G 1 |
| Pipe connection on the suction side DNs
|
Rp ½ |
| Pipe connection on the discharge side DNd
|
Rp ½ |
| Port-to-port length L0
|
84 mm |


| Fluid media |
Water 100 % |
| Fluid temperature T
|
20.00 °C |
| speed at duty point n hydr. @ OP
|
2900 1/min |